{"product_id":"phoenix-contact-umk-se-11-25-1-thermocouple-k-to-4-20ma-converter-6-channel-atls4307","title":"PHOENIX CONTACT UMK-SE 11,25-1 Thermocouple K to 4-20mA Converter 6-Channel","description":"\u003cp\u003ePHOENIX CONTACT UMK-SE 11,25-1 Thermocouple K to 4-20mA Converter 6-Channel\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable style=\"border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003ePHOENIX CONTACT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003eUMK-SE 11,25-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003eTyp UMK-SE 11,25-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eOrder No\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003e2970442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003eUMK universal module system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003eType K thermocouple to 4-20 mA signal converter module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eChannels\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eInput\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003eTC.K thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eOutput\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003e4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003e0-250 °C \/ 0-600 °C \/ 0-750 °C selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eBreak Detection\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003eMIN or MAX selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eGain Selection\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003eG0 \/ G1 \/ G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eCalibration\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003eZERO and GAIN adjustment per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003e77 x 11.25 x 39.5 mm per lateral element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003eTemperature signal conversion for control and instrumentation panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eCondition\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003ePRE-OWNED \/ SECOND HAND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd;font-weight:bold;background:#f7f7f7\"\u003eREF\u003c\/td\u003e\n\u003ctd style=\"padding:6px 12px;border:1px solid #ddd\"\u003eATLS4307\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cb\u003eShipping \u0026amp; Assurance:\u003c\/b\u003e Ships worldwide via DHL · UPS · Aramex. WhatsApp +91-814-038-5618 · sales@inmateto.com\u003c\/p\u003e","brand":"PHOENIX CONTACT","offers":[{"title":"Default Title","offer_id":45887045369925,"sku":"ATLS4307","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0758\/0463\/9301\/files\/atls4307-phoenix-contact-umk-se-11-25-1-thermocouple-k-to-4-20ma-converter-6-channel-al-reza-enterprise-inmateto-are-marine-1_result.jpg?v=1790593282","url":"https:\/\/www.inmateto.com\/products\/phoenix-contact-umk-se-11-25-1-thermocouple-k-to-4-20ma-converter-6-channel-atls4307","provider":"INMATETO","version":"1.0","type":"link"}